Richmond.gov.uk
My Account

Trading standards leaflets

Ref: 334886

2024.04.02 Recall: FlamePro Global Ltd Firefighter Jacket and Firefighter Trousers

The following notice has been issued by the Office for Product Safety and Standards.

Product
FlamePro Global Ltd Structural Firefighter Jacket and Structural Firefighter Trousers

Type
Personal protective equipment (PPE) - Firefighter jacket and firefighter trousers

Brand
FlamePro Global Ltd

Country of origin
Bulgaria

Product description
Firefighter's protective jacket and trousers designed to provide protection for the firefighter's torso, neck, arms to the wrists, and legs to the ankles during firefighting.

Flamepro firefighter

Product
FireFighter Jacket (770-VA5-HE4) and Structural Firefighter Trousers (775-VA5-HE4)

Affected batches
MWO-F_ 21106, 21047, 21006, 21048, 21107, 21200, 21007, 21045, 21104, 21004, 21046, 21198, 21105, 21256, 21201, 21199, 21254, 21005

Hazard
The firefighter jacket and trousers within the scope of the corrective action have been identified as presenting a risk of burns, as a result of the seams of the thermal lining breaking open and potentially exposing the wearer to excessive heat.

The main body of the jacket and trousers is made up of three layers of fabric. The thermal lining is the inner most layer in direct contact with the wearer's undergarment or station wear. The seams of the thermal lining, which are stitched to other lining pieces during manufacture, started to break open during wear. The areas of the garment where the thermal lining seams had opened would not provide the specified heat resistance, leaving the wearer without adequate heat protection.

The firefighting suit met the requirements of EN 469: 2020. However, this standard only requires strength testing of the outermost material. The strength of the thermal lining seams was not tested during the conformity assessment carried out before the product was placed on the market in Great Britain.

The firefighter jacket and trousers within the scope of the corrective action do not meet the requirements of Regulation (EU) 2016/425 on personal protective equipment.

Corrective action
FlamePro Global Ltd recalled all the affected firefighting jackets and trousers. They replaced the thermal lining with a heavier material with a seam strength exceeding 180 N, which was shown to be sufficient to maintain protection of the wearer during use. The modified structural firefighter suits were conformity assessed and recertified and then returned to the end user.

FlamePro Global Ltd will check that the seam strength of all fabrics used to make firefighting suits exceeds 180 N.

Full notice